FUJITSU MB91460 SERIES User Manual

Page 63

Advertising
background image

SK-91F467-FLEXRAY V1.1

Flash Programming

© Fujitsu Microelectronics Europe GmbH

- 63 -

FMEMCU-UG-910017-11

CAUTION : DO NOT INTERRUPT OR CUT OFF POWER DURING ERASE !!!

Chip-erase successful

Sending download command

loading and programming...

00148000: Security Address not programmed, use Prog Word!

00148004: Security Address not programmed, use Prog Word!

00148006: Security Address not programmed, use Prog Word!

001448008: Security Address not programmed, use Prog Word!

0014800C: Security Address not programmed, use Prog Word!

0014800E: Security Address not programmed, use Prog Word!

Download and programming completed

Automode finished.

COM port closed

automatically disconnect

Figure 6-2: FME Flash Programmer output message window

As shown in the message window the Security address is not programmed in
Automatic programming process. This is done for security reason to avoid the
activation of the Security function by accident.

8) After successful programming assert Reset or Power-off / On the board in order to

start the programmed application.

Note 1:
The MB91F467DA series is checking the serial UART4 interface
for valid string to enter Flash programming mode. For details
about boot sequence refer to Hardware Manual of MB91460
series.

Note 2:
Be aware of Security Features of MB91F467DA series. Check
Documentation of MB91460 series for detailed information!

Advertising
This manual is related to the following products: