7 can0 – can2, 8 lin / rs-232 uart, Can0 – can2 – FUJITSU MB91460 SERIES User Manual

Page 31: Lin / rs-232 uart

Advertising
background image

SK-91F467-FLEXRAY V1.1

Jumpers and Switches

© Fujitsu Microelectronics Europe GmbH

- 31 -

FMEMCU-UG-910017-11

3.7 CAN0 – CAN2

Three high-speed CAN-transceivers (PCA82C250) are on-board to connect all available on-
chip CAN to 9-pin D-Sub connectors (X9, X10 and X11).

JP82 Connects MCU RX0 to CAN transceiver U15

JP83 Connects MCU TX0 to CAN transceiver U15

JP87 Connects MCU RX1 to CAN transceiver U18

JP88 Connects MCU TX1 to CAN transceiver U18

JP89 Connects MCU RX2 to CAN transceiver U19

JP90 Connects MCU TX2 to CAN transceiver U19

Jumper

Setting

Description

ON (closed)

CAN0 RxD connected to MCU

JP82

OFF (open)

No connection to the microcontroller

ON (closed)

CAN0 TxD connected to MCU

JP83

OFF (open)

No connection to the microcontroller

ON (closed)

CAN1 RxD connected to MCU

JP87

OFF (open)

No connection to the microcontroller

ON (closed)

CAN1 TxD connected to MCU

JP88

OFF (open)

No connection to the microcontroller

ON (closed)

CAN2 RxD connected to MCU

JP89

OFF (open)

No connection to the microcontroller

ON (closed)

CAN2 TxD connected to MCU

JP90

OFF (open)

No connection to the microcontroller

Default: grey

Table 3-15: CAN-MCU connection

3.8 LIN / RS-232 UART

There are three UART connectors X1, X4 and X8 (9-pin D-Sub) on-board, which can be
used for RS-232 or LIN communication (to get information in detail about pin usage, please
refer to chapter 4.2 UART / LIN Connector (X1, X4, X8)). The LIN transceiver needs to be
configured as LIN-master or LIN-slave.

Advertising
This manual is related to the following products: