3 uart 5, Uart 5 – FUJITSU MB91460 SERIES User Manual

Page 34

Advertising
background image

SK-91F467-FLEXRAY V1.1

Jumpers and Switches

FMEMCU-UG-910017-11

- 34 -

© Fujitsu Microelectronics Europe GmbH

3.8.3 UART 5

UART5 (connector X8) is selected as RS-232 at default setting.
JP79 Select, if SIN5 is connected to RS-232- or LIN-transceiver

JP81 Select, if SOT5 is connected to RS-232- or LIN-transceiver

JP84 Select, if RS-232- or LIN-transceiver is connected to X8 pin2 (shared pin)

JP78 Some terminal programs needs a connection between CTS and RTS

JP80 Selects, if DTR or RTS will be used for system reset

generation

JP85 Enables the LIN transceiver

JP86 Selects, if UART5 will be LIN master or LIN slave

Jumper

Setting

Description

1-2

MCU SIN4 connected to RS-232 transceiver

JP79

2-3

MCU SIN4 connected to LIN transceiver

1-2

MCU SOT4 connected to RS-232 transceiver

JP81

2-3

MCU SOT4 connected to LIN transceiver

1-2

X4 pin2 is connected to RS-232 transceiver

JP84

2-3

X4 pin2 is connected to LIN transceiver

ON (closed)

RTS and CTS is connected at connector X4

JP78

OFF (open)

RTS and CTS is not connected at connector X4

1-2

DTR can be used for system reset

JP80

2-3

RTS can be used for system reset

ON (closed)

LIN transceiver is enabled

JP85

OFF (open)

LIN transceiver is not enabled

ON (closed)

LIN master mode

JP86

OFF (open)

LIN slave mode

Default: grey

Table 3-18: UART5 Settings

Note:
UART5 has to be selected with
JP57, to generates a system reset

Advertising