DEAN MILLIVOLT GAS FRYERS (CE)

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-7

3.4 Gas Connections (cont.)

3. If a vent line from the gas pressure regulator is used, it should be installed in accordance

with local codes or in the absence of local codes, with the appropriate national or
European Community (CE) standards.

WARNING

Use a diluted soap solution to find potentially dangerous gas leaks when making

new connections.


B. Regulators: Gas regulators can be adjusted in the field, but no adjustments should be made

unless the regulator is out of adjustment, or serious pressure fluctuations are observed.

C. Only qualified service personnel should make adjustments to the regulators.

D. Orifices: The fryer can be configured to operate on any available gas. The correct safety

control valve, appropriate gas orifices, and pilot burner are installed at the factory. While
the valve can be adjusted in the field, only qualified service personnel should make any
adjustments with the proper test equipment.

1. The following color codes indicate the type of gas to be used for each fryer and

associated components.

Gas Type

CE Color Code

Natural Blue

Propane Red

E. Flexible Couplings, Connectors and Casters

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the

installer must use a heavy-duty certified commercial flexible connector of at least 22 mm
NPT (with suitable strain-relief attachments), in compliance with local codes or in the
absence of local codes, with the appropriate national or European Community (CE)
standards. Quick-disconnect devices must comply with local codes or in the absence of
local codes, with the appropriate national or European Community (CE) standards.

2. For an appliance equipped with casters, the installation shall be made with a connector

that complies with local codes or in the absence of local codes, with the appropriate
national or European Community (CE) standards.

3. Under no circumstances are the connector and the quick-disconnect device, or its

associated piping to be used to limit fryer movement. A restraining bracket is provided on
the appliance back to prevent the unit from moving from its installed position.