DEAN MILLIVOLT GAS FRYERS (CE)

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-10


3.6 Gas Inputs (cont.)

A. Adjustments for different gases are as follows (cont.):

MODEL*

ORIFICE

SIZE (MM)

GAS TYPE

GAS PRESSURE AT

REGULATOR

BURNER

MARKING

PILOT

MARKING

SR 52GM
SM 50GM

2,40
2,40
1,51

G20
G25
G31

12,0
17,5
22,0

4,8
7,0
8,8

Blue
Blue

Red

26N
26N

16LP

SM 35GM
SR 38GM
SR 42GM

2,40
2,40
1,51

G20
G25
G31

12,0
17,5
22,0

4,8
7,0
8,8

Blue
Blue

Red

26N
26N

16LP

SM 20GM

2,40
2,40
1,51

G20
G25
G31

12,0
17,5
22,0

4,8
7,0
8,8

Blue
Blue

Red

26N
26N

16LP

*SR prefix- Super Runner Series

*SM prefix- Super Marathon Series

*GM suffix- gas millivolt system with no electrical supply connections required

(1) The Netherlands (NL) only.

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.

* For controls and adjustments, please refer to the gas valve illustration on page 3-12. (Pilot Flame

Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved).


WARNING

If gas odors are detected, the gas supply

MUST be shut off at the main shut-off

valve, and the local gas company or authorized service agency contacted for

immediate service.