3.6 Gas Inputs


Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Number and Quantity/Color are listed in the
table below:

MODEL NOMINAL

HEAT

INPUT- Qn

(kW)

GAS

TYPE

ORIFICE SIZE

(MM)

ORIFICE

PART NO.

ORIFICE
QTY/ COLOR

SM 80 GM

37.5

G20
G25
G31

2.40
2.40
1.51

810-2060
810-2060
810-2059

5/BLUE
5/BLUE

5/RED

SM 60 GM

37.5

G20
G25
G31

2.40
2.40
1.51

810-2060
810-2060
810-2059

5/BLUE
5/BLUE

5/RED

SR 52 GM
SM 50 GM

30

G20
G25
G31

2.40
2.40
1.51

810-2060
810-2060
810-2059

4/BLUE
4/BLUE

4/RED

SM 35 GM
SR 38G
SR 42G

26

G20
G25
G31

2.40
2.40
1.51

810-2060/*810-3101
810-2060/*810-3101
810-2059/*810-3102

3/BLUE
3/BLUE

3/RED

SM 20 GM

15

G20
G25
G31

2.40
2.40
1.51

810-2060
810-2060
810-2059

2/BLUE
2/BLUE

2/RED

*Use these orifices on SR42 fryers built after 4/07.


A. Adjustments for different gases are as follows:

GAS PRESSURE AT

REGULATOR

MODEL*

ORIFICE

SIZE (MM)

GAS TYPE

MBAR INCH

W.C.

BURNER

MARKING

PILOT

MARKING

SM 80GM

2,40
2,40
1,51

2,40(1)

G20
G25
G31

G25(1)

10,0
15,0
27,0

10,0(1)

4,0
6,0

10,8

4,0(1)

Blue
Blue

Red

Blue

26N
26N

16LP

26N

SM 60GM

2,40
2,40
1,51

G20
G25
G31

12,0
17,5
22,0

4,8
7,0
8,8

Blue
Blue

Red

26N
26N

16LP

*SR prefix- Super Runner Series

*SM prefix- Super Marathon Series

*GM suffix- gas millivolt system with no electrical supply connections required

(1) The Netherlands (NL) only.