Calibrating the Ribbon Sensor

Use this procedure (a) when colors on the printed card are out of alignment, (b) when a black
bar appears on the leading edge of the card or covers the entire card where the clear overlay
should be placed, or (c) when too many color panels are passed without being used.
Tools Needed

(1) Small standard screwdriver

(1) Full-color ribbon

(1) Dark colored note pad (or similar object)
Note: The Ribbon Sensor array can be affected by exposure to direct light. To ensure
proper operation, the Top Cover should be kept closed during normal operation. As it is
necessary to have the Top Cover open during the calibration procedure, place a dark colored
object such as a cardboard note pad over the Printhead Assembly to block light from
entering the printer.