14 read long command, 15 receive diagnostic results command – FUJITSU MCM3064AP User Manual

Page 140

Advertising
background image

Host Interface

4-70

C156-E227-01EN

4.6.14 READ LONG command

Table 4.96 READ LONG command

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (3Eh)

1

Logical Unit Number

Reserved

2-5

Logical Block Address

6

Reserved

7-8

Byte Transfer Length

9-11

Reserved

The READ LONG command reads data in the data, CRC, and ECC sections from
the specified logical block address.

The transfer byte length must be a multiple of 600 (258h) bytes for 512 byte media
and a multiple of 2380 (94Ch) bytes for 2048 byte media.

4.6.15 RECEIVE DIAGNOSTIC RESULTS command

Table 4.97 RECEIVE DIAGNOSTIC RESULTS command

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (1Ch)

1

Logical Unit Number

Reserved

2

Reserved

3-4

Allocation Length

5-11

Reserved

The RECEIVE DIAGNOSTIC RESULTS command transfers the diagnostic
results indicated by the SEND DIAGNOSTIC command to the host. The
RECEIVE DIAGNOSTC RESULT command must be issued following the
SEND DIAGNOSTIC command. If not issued continuously or if there is no data
to be transferred, the command transfers no data and ends normally.