4.3 Interface Register

C156-E227-01EN

4-7

4.3.1.1 Alternate Status register

This register contains the same information as that of the ATAPI Status register,
except that the ODD does not recognize interrupts when reading this register.
Therefore, the ODD does not clear the INTRQ signal and does not clear interrupts
during the pending.

Table 4.4 Bit definitions of Alternate Status register

7

6

5

4

3

2

1

0

BSY

DRDY

Reserved

(0b)

SERVICE

DRQ

CORR

(0b)

Reserved

(0b)

CHECK

Read

4.3.1.2 ATA Command register

This register contains a command to be passed to the ODD. The ODD starts
executing a command immediately after the command is written in this register.
For executable commands and required parameters, see Table 4.37.

4.3.1.3 Data register

The data register is used for data transfer. The data width is always 16 bits.

4.3.1.4 Device Control register

This register's bits are defined as shown below.

Table 4.5 Bit definitions of Device Control register

7

6

5

4

3

2

1

0

Reserved

Reserved

Reserved

Reserved

Reserved

SRST

nIEN

0

Write

Bits 7 to 3 are reserved. The ODD ignores all value sets in these bits.

SRST is a reset bit for host software.

nIEN is an enable bit for device interrupts to the host. When nIEN is 0 and
the device is selected, the INTRQ signal is enabled by the tri-state buffer.
When nIEN is 1 or the device is not selected, the INTRQ signal is in the high-
impedance state.

Advertising