FUJITSU MCM3064AP User Manual

Page 156

Advertising
background image

Host Interface

4-86

C156-E227-01EN

Table 4.118 Register/PIO data transfer timing parameters

Symbol

Timing parameter

min

(Units: ns)

max

(Units: ns)

Condition

t0

Cycle time

120

-

At mode 4,
no wait

t1

DIOR-/DIOW- setup time

25

-

t2

DIOR-/DIOW- pulse width

70

-

t2i

DIOR-/DIOW- recovery time

25

-

t3

DIOW- data setup time

20

-

t4

DIOW- data hold time

10

-

t5

DIOR- data setup time

20

-

t6

DIOR- data hold time

5

-

t6Z

DIOR- data High –Z time

-

30

t7

From address decided to IOCS16- asserted

-

30

t8

From address decided to IOCS16- released

-

30

t9

DIOR-DIOW- to address valid hold time

10

-

tA

IORDY setup time

-

35

PIO flow
control
transfer mode

tB

IORDY pulse width

-

1250

PIO flow
control
transfer mode

tRd

Read data valid to IORDY active

0

-