Installation Requirements

3-2

C156-E227-01EN

(a) Inside optical disk cartridge

Figure 3.1 Surface temperature measurement point

3.1.2 Temperature requirements

Table 3.1 shows the temperature requirement at the measurement point shown in
Figure 3.1.

Table 3.1 Temperature requirements at measurement points

Measurement point

Maximum allowable surface temperature

Inside the cartridge

55°C (*1)

IC (controller) surface

95°C

IC (read amp.) surface

85°C

*1

60°C for the optical disk cartridges recommended by Fujitsu (except 1.3
GB).

The following describes a procedure for measuring the temperature inside a
cartridge.

1)

At the bottom of the cartridge, open a hole large enough for the thermocouple
to be inserted as shown in Figure 3.1.

2)

Disassemble the cartridge.

3)

Cut off part of the wall surrounding the optical disk (disk outer wall) as shown
in Figure 3.1.

At this point, cut off a section 5 to 10 mm in width from the disk outer wall.

4)

Using an adhesive agent, affix the tip of the thermocouple to the opening of
the disk outer wall.

Hole for inserting thermocouple

Tip of thermocouple

Opening of disk outer wall