Table 4.120 Ultra DMA data out transfer parameter

Symbol

Timing parameter

min

(Units: ns)

max

(Units: ns)

Condition

t2CYCTYP

Average 2-cycle time

120

-

Mode 2

tCYC

Cycle time (for non-target clock and at
clock change)

54

-

t2CYC

2-cycle time (at clock change)

115

-

tDS

Data setup time on receiving side

7

-

tDH

Data hold time on receiving side

5

-

tDVS

Data enabled setup time on sending side

30

-

tDVH

Data enabled hold time

6

-

tFS

First strobe time

0

170

tLI

Restricted interlock time

0

150

tMLI

Minimum interlock time

20

-

tUI

Non-restricted interlock time

0

-

tAZ

Driver Maximum release time

-

10

tZAH

Output delay time

20

-

tZAD

Driver Assert and negate time

0

-

tENV

Envelope time

20

70

tSR

STROBE to DMARDY time

-

20

tRSF

Ready to the last STROBE time

-

60

tRP

Ready to stop time

100

-

tIORDYZ

Maximum IORDY release time

-

20

tIORDDY

STROBE operation minimum time

0

-

tACK

DMACK- setup and hold time

20

-

tSS

STROBE edge to DMARQ negate and
assert time

50

-