4.5 ATA Commands

C156-E227-01EN

4-27

Table 4.19 Device parameter information (3/5)

Word

Value

Bits

Description

72

03E8h (1000)

Required time after the SERVICE command is received until
BSY is cleared (

µ

s) (Typical)

73-79

0000h

Reserved

80

0010h

Major Version number (ATA/ATAPI-5)

81

0000h

Minor Version number (ATA/ATAPI-5 T13 1321D revision 1)

82

4278h

Command set supported
(A value of less than 1 indicates that the command is
supported.)

15

IDENTIFY DEVICE DMA command (0b)

14

NOP command (1b)

13

READ BUFFER command (0b)

12

WRITE BUFFER command (0b)

11

WRITE VERIFY command (0b)

10

Host protect area function (0b)

9

DEVICE RESET command (1b)

8

SERVICE command interrupt (0b)

7

Interrupt at release (0b)

6

Read ahead cache (1b)

5

Write cache (1b)

4

Packet command function (1b)

3

Power management function (1b)

2

Removable media function (0b)

1

Security mode (0b)

0

SMART function (0b)

83

4000h

Command set supported
(A value of less than 1 indicates that the command is
supported.)

15

0b.

14

1b

13-1

Reserved

0

DOWNLOAD MICROCODE command supported (0b)

84

4000h

Command set supported

15

0b