Chapter 8 troubleshooting, 8 troubleshooting 117 – Fortress Technologies ecure Wireless Access Bridge User Manual

Page 127

Advertising
background image

Fortress Bridge: Troubleshooting

117

Chapter 8

Troubleshooting

Problem

Solution

You are unable to

access the Bridge GUI.

Verify the Bridge’s physical connection:
• from an Ethernet port on a computer or a network switch to one of the

Bridge’s unencrypted internal LAN ports.

—or—
• from a computer running the Fortress Secure Client in the Bridge’s

encrypted zone.

Verify the browser link:
• the computer you are using to access the Bridge GUI is in the same

subnet as—or has a network route to—the Bridge’s
IP address.

• you are using

https

(hypertext transfer protocol with Secure Socket

Layer), rather than simple http to connect to the Bridge GUI.

• you are using the correct IP address and subnet mask to connect

(the default is 192.168.254.254, subnet mask 255.255.255.0).

• if you just changed Bridge’s IP address, you have closed the browser

window you last used to access the Bridge GUI and opened a new
browser window to access its new address.

Verify the Bridge GUI’s accessibility:
• the Bridge GUI has not been disabled in the Bridge CLI.
• no one is logged on to the Bridge CLI.
• the Bridge’s IP address has not changed.

You are unable to

access the Bridge CLI.

• Verify that your serial application is using the correct settings:

bps=38400, data bits=8, parity=none, stop bits=1, flow control=none

• If you are connecting directly to the Bridge’s

Console

port, verify the

physical connections.

• If you are connecting remotely, verify that SSH has been enabled

through the

Console

port. (SSH is disabled by default.)