1 maximum user authentication retries, 1 default user authentication settings, 2 individual user authentication settings – Fortress Technologies ecure Wireless Access Bridge User Manual

Page 66

Advertising
background image

Fortress Bridge: Administration

56

on the

AUTHENTICATION

SETTINGS

frame of the

SECURITY

SETTINGS

screen.

On a Fortress Bridge-secured network, user authentication can
be used by itself or combined with device authentication. The
options that determine whether device authentication is
enabled are also configured globally, in the

AUTHENTICATION

SETTINGS

frame of the

SECURITY

SETTINGS

screen.

NOTE:

Refer to

Section 3.6.6.1 and

for instructions on glo-
bally enabling

Local

au-

thentication and to
Section 3.6.6.4 for in-
structions on enabling
device authentication.

4.2.1

Maximum User Authentication Retries

The maximum number of unsuccessful authentication attempts
a user will be allowed before being locked out is another global
setting; the same setting configures the maximum number of
times devices can unsuccessfully attempt to authenticate on
the network. (Refer to Section 3.6.6.5 for detailed instructions.)

If a user exceeds the maximum allowable retry attempts to log
on to the Bridge-secured network, s/he will be locked out until
you reset the session.

4.2.1

Default User Authentication Settings

NOTE:

Refer to

Section 3.6.6.7 for

detailed instructions on
configuring default user
authentication settings.

While idle timeout and session timeout settings can be
individually configured for each user, the default values for
these settings are determined by the

AUTHENTICATION

DEFAULTS

set in the

AUTHENTICATION

SETTINGS

frame of the

SECURITY

SETTINGS

screen.

4.2.2

Individual User Authentication Settings

User authentication on the Fortress Bridge requires the usual
settings to identify, track and manage access for each user on
the Fortress-secured network:

‹

Username

- identifies the user on the network—from 1 to 16

alphanumeric characters—required.

‹

Full Name

- associates the person, by name, with his/her

user account—up to 64 alphanumeric characters, including
spaces, dashes, dots and underscores—optional.

‹

Password/Verify Password

- establishes the credentials the

user must key in to access his/her user account—from 4 to
16 alphanumeric characters, including shifted numeral-key
symbols—required.

‹

Idle Timeout

- sets the amount of time the user’s device can

be idle on the network before it must renegotiate keys with
the Bridge.

Idle Timeout

is set in minutes, between 0 and 9999. A value

of zero disables idle timeout for that user (his device can be
idle indefinitely without timing out). If you enabled

Local

authentication while leaving the settings under

AUTHENTICATION

DEFAULTS

(Section 3.6.6.7) at their

defaults, the

Idle Timeout

value in the

ADD

USER

frame will

be at 30 minutes.

Advertising