Venting installation, 10 foot rule, Continued finishing fireplace – FMI (V)B42LI User Manual

Page 12

Advertising
background image

www.fmiproducts.com

109036-01M

12

10'

2' Min.

10'

3' Min.

2' Min.

3' Min.

Level of

Flue Gas

Outlet

Figure 19 - 10 Foot Rule

10 FOOT RULE

All flue gas outlet chimney terminations must

extend a minimum of 3 feet in height above

highest point where it passes through roof and

must be at least 2 feet above highest point of

the roof that is within a horizontal distance of

10 feet (see Figure 19).

VENTING INSTALLATION

Continued

FINISHING FIREPLACE

Combustible materials, such as wallboard,

gypsum board, sheet rock, drywall, plywood,

etc., may make direct contact with sides and

top around fireplace face. It is important that

combustible materials do not overlap face

itself. Brick, glass, tile or other noncombustible

materials may overlap front face provided

they do not obstruct essential openings such

as louvered slots. When overlapping with

a noncombustible facing material, use only

noncombustible mortar or adhesive.

30E-8DM

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

EFFECTIVE HEIGHT
OF TERMINATION CAP

MINIMUM
HEIGHT

14.5 FT.

MINIMUM

UP TO
6FT. MAX.

UP TO
6FT. MAX.

HEIGHT

14.5 FT.

MIN. HEIGHT
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.

MAX. HEIGHT
50 FT.
(ANY SYSTEM)

30E-8DM