HEARTH EXTENSION

A hearth extension projecting a minimum of

20" in front of and a minimum of 12" beyond

each side of fireplace opening is required to

protect combustible floor construction in front

of fireplace. Fabricate a hearth extension

using a material which meets the following

specifications: a layer of noncombustible,

inorganic material having a thermal conductiv-

ity of K=0.84 BTU IN/FT, HR. F (or less) at 1"

thick. For example, if material selected has

a K factor of 0.25, such as glass fiber, the

following formula would apply:

0.25 x 1.0" = 0.30" thickness required

0.84

Thermal conductivity "K" of materials can be

obtained from manufacturer or supplier of

noncombustible material. If hearth extension

is to be covered, use noncombustible mate-

rial such as tile, slate, brick, concrete, metal,

glass, marble, stone, etc. Provide a means

to prevent hearth extension from shifting and

seal gap between fireplace frame and hearth

extension with a noncombustible material

(see Figure 3).

WARNING: Hearth extension

is to be installed only as shown

in Figure 3.

FIREPLACE INSTALLATION

Figure 3 - Hearth Extension

Seal Gap

Fireplace Front

Ember Protector

Fireplace Front

Raised Hearth

Fireplace Front

Elevated

Ember Protector

Ember Protector

Seal Gap

Hearth

Extension

Seal Gap

Fireplace Front

Ember Protector

Fireplace Front

Elevated

Do Not Block Louver

Ember Protector

Seal Gap

Hearth

Extension

Hearth Extension, Circulating Modes

Hearth Extension, Noncirculating Models