Venting installation, Optional outside air kit (model ak4/ak4f), Chimney pipe – FMI (V)B42LI User Manual

Page 7

Advertising
background image

www.fmiproducts.com

109036-01M

7

Figure 8 - Lineal Gain

Hemmed

End

8" Stainless

Inner Pipe

12

3

/

8

"

Galvanized

Outer Pipe

Figure 7 - Outside Air Kit

Secure to Collars with Metal Tape, Screws

or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

Installation of outside air kit should be per-

formed during rough framing of fireplace due

to the nature of it's location. Outside combus-

tion air is accessed through a vented crawl

space (AK4F) or through a sidewall (AK4).

See Figure 24 on page 15 for instruction of

operating air kit.

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

CHIMNEY PIPE

FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned

for maximum adaptability to individual site

requirements. Actual lengths gained after fit-

ting overlaps must be taken into consideration

(lineal gain) and are given in lineal gain chart

(see Figure 8).
Lineal gain is actual measurable length of a

part after two or more parts are connected.

WARNING: The opening in

collar around chimney at top of

fireplace must not be obstructed.

Never use blown insulation to fill

chimney enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37

1

/

2

"

12-8DM

12-8HT

Pipe Section

10

5

/

8

"

18-8DM

18-8HT

Pipe Section

16

5

/

8

"

24-8DM

24-8HT

Pipe Section

23

5

/

8

"

36-8DM

36-8HT

Pipe Section

34

5

/

8

"

48-8DM

48-8HT

Pipe Section

46

5

/

8

"

RT-8DM

Round Termination

6

7

/

8

"*

RTL-8DM

Round Termination

7

3

/

4

"*

RLT-8DM

Round Termination

7

1

/

2

"*

RTT-8DM

Round Termination

with Slip Section

6

7

/

8

" to

23

1

/

8

"*

RTTL-8DM Round Termination

with Slip Section

8

1

/

2

" to

21

1

/

2

"*

RLTT-8DM Round Termination

with Slip Section

7

1

/

2

" to

21

1

/

4

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

with Mesh

12"*

ETL-8DM

Square Chase-Top

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top

with Mesh & Slip

Section

12" to

25

1

/

2

"*

* The lineal gain for the terminations is

measured to the flue gas outlet height.