VENTING INSTALLATION

Continued

Figure 9 - Typical Offset Installation

Return

Elbow

Offset

Elbow

Return

Elbow

Offset

Elbow

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

Return

Elbow

Offset

Elbow

Offset

Elbow

Return

Elbow

A

B

C

Offset

Elbow

Ceiling

Support Pipe

12S-8DM

Return

Elbow

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists

of a galvanized outer pipe, a stainless steel

inner flue pipe and a wire spacer. Pipe sec-

tions must be assembled independently as

chimney is installed. When connecting chim-

ney directly to fireplace, inner flue pipe sec-

tion must be installed first with lanced side

up. Outer pipe section can then be installed

over flue pipe section with hemmed end up.

Press down on each pipe section until lances

securely engage hem on fireplace starter.

Wire will assure proper spacing between

inner and outer pipe sections.
Note: For Canada, use chimney parts des-

ignated HT.

Opening in collar around

chimney at top of fireplace must

not be obstructed. Never use

blown insulation to fill chimney

enclosure.

Continue to assemble chimney sections as

outlined, making sure that both inner and

outer pipe sections are locked together. When

installing double wall snap-lock chimney to-

gether, it is important to assure joint between

chimney sections is locked. Check by pulling

chimney upward after locking. Chimney will

not come apart if properly locked. It is not

necessary to add screws to keep chimney to-

gether (exception - see Figure 11, page 9).

USING ELBOW OFFSETS (30E-8DM)

1. To achieve desired offset, you may install

combinations of 12", 18", 24", 36" and

48" length of double wall pipe (see offset

chart, page 7, and Figure 9).

Note: For systems with 2 elbow sets, mini-

mum height is 22 feet. Maximum height

for any system is 50 feet.

2. Chimney weight above offset rests on

return elbow. Straps must be securely

nailed to rafters or joists (see Figure 10,

details A and B, page 9).

3. Maximum length of pipe between supports

(return elbow or 12S-8DM) is 6' of angle

run. Maximum of two 6' angle run sections

per chimney system (see Figure 9).

4. All pipe connections between offset and

return must be secured with two screws

on outer pipe only (see Figure 11, page

9). Do not penetrate inner stainless.