iNsTallaTioN

Continued

FIREPLACE CLEARANCES

WARNING: Maintain the

minimum clearances shown

in Figure 6. If you can, provide

greater clearances from floor,

ceiling and joining wall.

NOTICE: If you install the fire-

place in a bedroom, some

building codes require that the

fireplace/mantel system be se-

cured to (or within) a wall. You

can position fireplace in an op-

tional cabinet or corner mantel.

You can also recess fireplace

into the wall.

If your fireplace is to be used with an optional
mantel, the installation instructions included
with your mantel shows an CSA approved
method of attaching the fireplace/mantel sys-
tem to a wall. IMPORTANT: Only use optional
cabinet or corner mantels specified in this
manual. Purchase the optional mantel from
your dealer (see Accessories, page 34).
If your fireplace is to be recessed into the wall,
see Built-In Fireplace Installation to secure
your fireplace into the wall.

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18" above floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fire-
place
• where there is easy access for operation,

inspection and service

• in coldest part of room

Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and
wall should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3

1

/

2

" from the wall. This com-

bustible material must be 4" from the side
of the fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 36".

C. For mantel clearances, see Figure 9 on

page 12.

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

*

Example

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Right Sides

Bottom and

Rear

Front

36"

6"

0"

36"

bUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with
wall. Fireplace face will extend past sides
and top of fireplace approximately 1". This will
cover the rough edges of the wall opening. If
installing a built-in mantel above the fireplace,
you must follow the clearances shown in Fig-
ure 9, page 12. To install the fireplace in this
manner, use the following instructions.