Continued

We recommend that you install a sediment
trap in supply line as shown in Figure 14. Lo-
cate sediment trap where it is within reach for
cleaning. Install in piping system between fuel
supply and heater. Locate sediment trap where
trapped matter is not likely to freeze. A sediment
trap traps moisture and contaminants. This
keeps them from going into fireplace controls.
If sediment trap is not installed or is installed
wrong, fireplace may not run properly.

* Purchase the optional equipment shutoff
valve from your dealer. See Accessories,
page 34.

Figure 14 - Gas Connection

Equipment Shutoff
Valve With 1/8" NPT
Tap*

3" Minimum

Approved
Flexible Gas
Line

Pipe Nipple Cap Tee Joint

Propane/LP
From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)

NATURAL
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)

Sediment Trap

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas

line is provided to allow acces-

sibility from the fireplace (see

Figure 1, page 5). The flexible

gas supply line connection to the

equipment shutoff valve should

be accessible.

Figure 15 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

Flexible Gas Line
from Fireplace Gas
Regulator Provided
With Fireplace

To Gas Regulator
(Manual-Controlled
Models) or Control
Valve (Remote-
Ready Models)

Equipment
Shutoff Valve

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

1. Route flexible gas line, included, from

fireplace control to equipment shutoff
valve through side or rear access holes
in outer casing (see Figure 1, page 5).

2. Apply pipe joint sealant lightly to male

threads of gas connector attached to
flexible gas line/equipment shutoff valve
(see Figure 15).

CAUTION: Avoid damage to

regulator. Hold gas regulator with

wrench when connecting it to gas

piping and/or fittings (Manual-

Controlled Models Only).

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting

it to gas piping and/or fittings

(Remote-Ready Models Only).

3. Check all gas connections for leaks. See

Checking Gas Connections.

4. Feed flexible gas line into fireplace base

area while replacing branch support. Make
sure the entire flexible gas line is in fireplace
base area.