Operating fireplace – FMI CGMFN User Manual

Page 19

Advertising
background image

www.fmiproducts.com

119315-01D

19

OFF

PILOT

ON

opERaTiNG FiREplaCE

Continued

D. Do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the screen

in place. Make sure fireplace

screen is installed before run-

ning fireplace.

NOTICE: During initial opera-

tion of new fireplace, burning

logs will give off a paper-burn-

ing smell. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information,

page 18.

2. Make sure equipment shutoff valve

is fully open.

3. Turn control knob clockwise

to

the OFF position.

4. Wait five (5) minutes to clear out any

gas. Then smell for gas, including
near the floor. If you smell gas, STOP!
Follow “B” in the safety information,
page 18. If you don’t smell gas, go to
the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press in

control knob for five (5) seconds (see
Figure 23).

Note: You may be running this fireplace
for the first time after hooking up to
gas supply. If so, the control knob may
need to be pressed in for 30 seconds or
more. This will allow air to bleed from
the gas system.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

6. With control knob pressed in, press and

release ignitor button (see Figure 23).
This will light pilot. The pilot is attached
to the front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to
Troubleshooting
, page 31. Also, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure
on page 20.

7. Keep control knob pressed in for 30

seconds after lighting pilot. After 30
seconds, release control knob.

Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety
interlock system. Wait one (1) minute
for system to reset before lighting
pilot again.

8. Turn control knob counterclockwise

to ON position. The burner

should light.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 23 - Control Knob In The OFF

Position

Piezo Ignitor

Control Knob

Figure 24 - Natural Gas Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

Thermocouple

Ignitor
Electrode

Pilot
Burner

Figure 25 - Propane/LP Gas Pilot