iNsTallaTioN

Continued

Actual Framing

Height

23

3

/

4

"

22

1

/

4

"

Front Width 19

3

/

4

"

17

1

/

2

"

Depth

8

7

/

8

"

8

7

/

8

"

Bottom

0"

0"

1. Frame in rough opening. Use dimensions

shown in Figure 7 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 8 for the rough opening.
The height is 22

1

/

4

" which is the same as

the wall opening above.

2. Install gas piping to fireplace location. This

installation includes an approved flexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible
gas line must be the last item installed on
the gas piping.

3. If you have not assembled firebox, follow

instructions on page 6.

4. Carefully set fireplace in front of rough

opening with back of fireplace inside wall
opening.

5. Attach flexible gas line to fireplace gas

regulator. See Connecting Fireplace to
Gas Supply,
page 14.

6. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

17

1

/

2

"

22

1

/

4

"

8

7

/

8

"

Figure 8 - Rough Opening for Installing

in Corner

Figure 7 - Rough Opening for Installing

in Wall

29

7

/

8

"

21

1

/

8

"

42

1

/

4

"

17

1

/

2

"

IMPORTANT: When finishing your firebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and
top edge of the firebox. Combustible materials
should never overlap the firebox front facing.

WARNING: Do not allow any

combustible or noncombustible

materials to overlap the firebox

front facing.

WARNING: Do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you
must meet minimum clearance between man-
tel shelf and top of fireplace opening.

NOTICE: Surface temperatures

of adjacent walls and mantels

become hot during operation.

Walls and mantels above the

firebox may become hot to

the touch. If installed properly,

these temperatures meet the

requirement of the national

product standard. Follow all

minimum clearances shown in

this manual.

NOTICE: If your installation

does not meet the minimum

clearances shown in Figure 9,

page 12, you must do one of the

following:

• raise the mantel to an accept-

able height

• remove the mantel