Operating fireplace – FMI CGMFN User Manual

Page 21

Advertising
background image

www.fmiproducts.com

119315-01D

21

opERaTiNG FiREplaCE

Continued

4. Wait five (5) minutes to clear out any

gas. Then smell for gas, including
near the floor. If you smell gas, STOP!
Follow “B” in the safety information,
page 20. If you don’t smell gas, go to
the next step.

5. Press in and turn control knob coun-

terclockwise

to the PILOT posi-

tion. Press in control knob for five (5)
seconds (see Figure 26, page 20).

Note: You may be running this fireplace
for the first time after hooking up to
gas supply. If so, the control knob may
need to be pressed in for 30 seconds or
more. This will allow air to bleed from
the gas system.

6. With control knob pressed in, press and

hold electronic ignitor button. This will
light pilot. The pilot is attached to the
front of the burner. If needed, keep press-
ing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact
a qualified service person or gas sup-
plier for repairs. Until repairs are made,
light pilot with match. To light pilot with
match, see Manual Lighting Procedure
.

7. Keep control knob pressed in for 30

seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4
through 8.

8. Slightly push in and turn control knob

counterclockwise

to the ON

position.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

9. To turn off burner and leave pilot lit:

Turn control knob clockwise

to

the PILOT position. If using optional
hand-held remote, set remote switch
to the OFF position to prevent draining
battery.

TO TURN OFF GAS

TO APPLIANCE

1. Turn control knob clockwise

to

the OFF position.

2. If Using Optional Hand-Held Remote:

Set remote switch to the OFF position
to prevent draining battery.

3. Close equipment shutoff valve (see

Figure 16, page 15)

WARNING: Make sure remote

sensor selector switch is in the OFF

position when you are away from

home for long periods of time.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Light-

ing Instructions, page 20.

2. Depress control knob and light pilot

with match.

3. Keep control knob pressed in for 30

seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 under Lighting Instruc-
tions
, column 1.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must
be purchased separately (see Accessories,
page 34). Follow instructions included with
the remote control.
Note: Refer to installation instructions
included with optional remote control for
remote operation.

Figure 27 - Propane/LP Gas Pilot

Ignitor
Electrode

Pilot
Burner

Figure 28 - Natural Gas Pilot

Ignitor
Electrode

Pilot Burner

Advertising
This manual is related to the following products: