Troubleshooting – FMI CGMFN User Manual

Page 27

Advertising
background image

www.fmiproducts.com

119315-01D

27

TRoUBlEshooTiNG

Continued

ObSERVED PRObLEM

Delayed ignition of burner

Burner backfiring during com-
bustion

Slight smoke or odor during
initial operation

Fireplace produces a whistling
noise when burner is lit

White powder residue forming
within burner box or on adja-
cent walls or furniture

Moisture/condensation no-
ticed on windows

POSSIbLE CAUSE

1. Manifold pressure is too

low

2. Burner orifice is clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner
3. Gas regulator defective
4. Inlet gas pressure is too

low

1. Residues from manufac-

turing processes and log
curing

2. Not enough air

3. Gas regulator defective

1. Turning control knob to HI

position when burner is
cold

2. Air in gas line

3. Air passageways on fire-

place blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors

from furniture polish, wax,
carpet cleaners, etc. may
turn into white powder
residue

1. Not enough combustion/

ventilation air

REMEDY

1. Contact local natural or

propane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 24)
or replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 24)
or replace burner orifice

2. Replace damaged burner
3. Replace gas regulator
4. Contact local natural or

propane/LP gas company

1. Problem will stop after a few

hours of operation

2. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 24)

3. Replace gas regulator

1. Turn control knob to LO

position and let warm up
for a minute

2. Operate burner until air is

removed from line. Have
gas line checked by local
natural gas company

3. Observe minimum installa-

tion clearances (see pages
10 through 13)

4. Clean burner (see Cleaning

and Maintenance, page 24)
or replace burner orifice

1. Turn fireplace off when

using furniture polish, wax,
carpet cleaners or similar
products

1. Refer to Air for Combustion

and Ventilation require-
ments (page 6)

Advertising