ClEaNiNG aND MaiNTENaNCE

Continued

TRoUBlEshooTiNG

WARNING: Turn off and unplug fireplace and let cool before

servicing. Only a qualified service person should service and repair

fireplace.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

POSSIbLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or

wet

3. Broken ignitor cable
4. Bad ignitor
5. Ignitor electrode posi-

tioned wrong

6. Ignitor electrode broken
7. Battery not installed, bat-

tery power low or battery
not installed correctly

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing.
Keep ignitor cable dry

3. Replace ignitor cable
4. Replace ignitor
5. Replace pilot assembly

6. Replace pilot assembly
7. Install new alkaline battery

in electronic ignitor. Verify
battery is installed cor-
rectly

ObSERVED PRObLEM

When ignitor button is pressed,
there is no spark at ODS/pi-
lot

LOG SET

• If you remove one-piece log set for clean-

ing, refer to Installing Log Set and Screen,
page 18, for placement instructions.

• Replace log set if broken or chipped (dime-

sized or larger).

CABINET

Air Passageways
Use pressurized air to clean.

Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to remove
dust.