Specifications, Wiring diagram, Service hints – FMI CGMFN User Manual

Page 29: Technical service, Replacement parts, Specifications service hints

Advertising
background image

www.fmiproducts.com

119315-01D

29

spECiFiCaTioNs

sERViCE hiNTs

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas sup-

ply may be low

You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.

TEChNiCal sERViCE

You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact FMI PRODUCTS, LLC’s Technical
Service Department at 1-866-328-4537.
When calling, please have your model and
serial numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com.

REplaCEMENT paRTs

Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call FMI PRODUCTS, LLC’s Technical Ser-
vice Department at 1-866-328-4537.
When calling FMI PRODUCTS, LLC, have
ready
• your name
• your address
• model and serial numbers of your fire-

place

• how fireplace was malfunctioning
• type of gas used (propane/LP or natural

gas)

• purchase date
Usually, we will ask you to return the part to
the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call FMI PRODUCTS, LLC at 1-866-328-4537
for referral information.
When calling FMI PRODUCTS, LLC, have
ready
• model number of your fireplace
• the replacement part number

WiRiNG DiaGRaM

(REMOTE-READY MODELS ONLY)

Red

Jumper Wire

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

CGMFP
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
VGMRP
• Rating: 10,000 Btu/Hr
• Gas Type: Propane/LP
Ignition: Electronic Ignitor
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14", Minimum* - 11"
* For purpose of input adjustment

CGMFN
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
Ignition: Piezo
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
VGMRN
• Rating: 10,000 Btu/Hr
• Gas Type: Natural
Ignition: Electronic Ignitor
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5", Minimum* - 5"
* For purpose of input adjustment

ALL MODELS
• Dimensions (HxWxD): Fireplace (including hood and screws) - 23

3

/

4

" x 19

3

/

4

" x 8

7

/

8

"

• Weight: Fireplace - 30 lbs., Shipping:

33

lbs.

Advertising
This manual is related to the following products: