B3.14 setting picking time, B3.15 setting time-out limit, B3.14 – FUJITSU M3099EX/EH User Manual

Page 213: B3.15

Advertising
background image

M3099EX/EH OEM Manual

B-11

SETUP MODE

39 Press [Mode 1] and [Mode 2] at a time to see

Screen 25. The settings are stored to
EEPROM.

40 When you close the setup mode, go to 9.

B3.14 Setting picking time

When you set the picking time, you must set as follows.

41 At Screen 2, press [Mode 1] fourteen times to

go to the PICK TIMER screen. (Screen 27)

42 Press [Mode 2] to see Screen 28. (The default

setting is 2 sec.)

43 At Screen 28, press [Mode 1] until the digit

you want to change blinks. Then press [Mode
2] until the digit changes as you want. (The
specifiable range is from 0.5 to 99.5 sec. in
0.5 sec. step.)

44 Press [Mode 1] and [Mode 2] at a time to see

Screen 27. The settings are stored to
EEPROM.

45 When you close the setup mode, go to 9 .

B3.15 Setting time-out limit

When you set the time-out limit, you must set as follows.

46 At Screen 2, press [Mode 1] fifteen times to

go to the TIME-OUT SET screen. (Screen
29)

47 Press [Mode 2] to see Screen 30. (The default

setting is 30 sec.)

<< SETUP MODE >>

PICK TIMER

Screen 27

<< SETUP MODE >>

X X . X

S

Screen 28

<< SETUP MODE >>

TIME-OUT SET

TIME-OUT SET

X X X X

S

Screen 30

Screen 29

Advertising