Interface specifications, Control interface, Connection specifications – FUJITSU M3099EX/EH User Manual

Page 29: Interface specifications -1 control interface -1, Connection specifications -1, Chapter 3: interface specifications, Connection specifications control interface

Advertising
background image

M3099EX/EH OEM Manual

3-1

INTERFACE
SPECIFICATIONS

3

CHAPTER

INTERFACE SPECIFICATIONS

This section describes the control interface between the host
computer and the scanner. For details of the interface, refer to the
EIA RS-232C standard.

Connection specifications

Control Interface

Item

Transmission system

Synchronization system

Data length

Stop bit

Data check

Data transfer rate

Maximum connection

Standard

Specification

Half-duplex

Start-stop

8 bits

1 bit

Odd parity check

1200, 2400, 4800, 9600 bps

5 m (16 ft.)

EIA RS-232C

Remark

Set by
EEPROM
on Interface
PCA
Default:
4800 bps

D

1

D

0

D

2

D

3

D

4

D

5

D

6

D

7

P

Stop
bit

Start bit

Advertising