C-1

SEPARATION
PRESSURE
ADJUSTMENT

APPENDIX

C

SEPARATION PRESSURE ADJUSTMENT

Adjust the separation pressure as follows:

WARNING

Wait at least 3 minutes after turning off the power before replacement.

ACHTUNG

Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem
Austausch beginnen.

Roller ASY

Lever (green)

Power switch

Upper transport unit

Lever

1 Turn off the power switch.

Make sure that the hopper
table is at the bottom.

2 Open the upper transport unit.

(See page 4-2)

3 Disconnect the two relay

connectors on the roller ASY.

4 Push the two levers (green)

towards each other to dis-
engage with the upper locking
holes and lower down the two
levers until they engage with
the two levers locking holes.