Software functional overview – FIC M296 User Manual

Page 88

Advertising
background image

Software Functional Overview

Register

Bit Number

Function Address

Name

R/W

7 6 5

4

3

2

1

0

Logic Default Description

6Ch

PMU_LOW_

ADR

R/W DATA

[7:0] -

-

6Dh

PMU_HIG_

ADR

R/W DATA

[15:8] -

-

6Eh

CHECK_

SUM

R/W DATA

[7:0] -

-

PMU

Access

6Fh PMU_DATA

R/W

DATA

[7:0]

-

-

These registers are available when
PMU slave mode or charger mode is
selected.
For detail information, refer to PMU
slave communication section in this
document

70h

*7

SMB_PTCL R/W

PROTOCOL[7:0]

-

-

71h

*7

SMB_STS R/W

D
O
N

E

A

L
R

M

R
E

S

STATUS

[4:0]

- -

72h SMB_ADDR R/W

ADDRESS

[6:0]

R
E

S

- -

73h SMB_CMD R/W

COMMAND

-

-

74h

to

93h

SMB_DATA
[0-31]

R/W DATA -

-

94h SMB_BCNT R/W RES[7:5]

BCNT[4:0]

-

-

95h

SMB_
ALARM_
ADDR

R(/W) ADDRESS[6:0]

R
E

S

- -

96h

to

97h

AMB_
ALARM_
DATA[0-1]

R(/W) DATA -

-

For detail information, refer to ACPI
1.0 specification
[ 13.9 SMBus Host controller
Interface via Embedded controller]

These registers are not available when
PMU slave mode or charger mode is
selected.

The PMU06 has access protect
function for the EEPROM in the
battery, to cancel the protection, set
the access protect cancel bit.
For detail, refer to SMBus section

SMBus

98h SMB_CNRL R/W

RES[7:1]

P

R
T

0x00

PRT =1 :

The SMBus address
(A8-AE) protection
is cancelled.

Reserved

99h

to

9Fh

Reserved R/W

Don't

care

- -


*7:

When this register is checked by polling, the interval time is necessary more than 500usec.

R(/W):

This is the read only register, but the written data will be able to read back till PMU updates the data
periodically, or PMU detects the status change.


3-38

FIC M295 / M296 Service Manual

Advertising
This manual is related to the following products: