Software functional overview – FIC M296 User Manual

Page 92

Advertising
background image

Software Functional Overview

Register

Bit Number

Function Address

Name

R/W

7 6 5

4

3

2

1

0

Logic

De-

fault

Description

D0h

BAT_CHG_
CONT

R/W RES[7:5]

C
H
G
_
R
D
Y
#

RES

[3:2]

C
H
G

2

C
H
G

1

- -

CHG_RDY# =0 : Charge ready
CHGn =1 : The nth battery is
charged

D1h

BAT_DCH_
PRI

R/W RES[7:3]

PAT

[2:0]

- 0x00

Battery discharge priority
0 : 2 1
1 : 1 2
2 : 2 1
3 : 2 1
4 : 1 2
5 : 1 2
6 : Same as 0
7 : Simultaneously discharge (Read
only :This data can be set using
PMU register)

D2h

BAT_DCH_
CONT

R/W RES[7:2]

D
C
H
G

2

D
C
H
G

1

0: Not
discharge
1:
Discharge

-

The discharge battery can be
selected one of the batteries can be
discharged.

D3h

BAT_WAR_
ABS

R/W DATA[15:0]

*1

-

0x000

0

Absolute capacity battery Warning
detection point
0x0000-0xffff (mWh)

D5h

BAT_LOW_
ABS

R/W DATA[15:0]

*1

-

0x000

0

Absolute capacity battery Low
detection point
0x0000-0xffff (mWh)

D7h

BAT_WAR_
REL

R/W DATA

[7:0]

-

0x10

Relative capacity battery Warning
detection point
00-C8h (0-100% step 0.5%)

D8h

BAT_LOW_
REL

R/W DATA

[7:0]

-

0x06

Relative capacity battery Low
detection point
00-C8h (0-100% step 0.5%)

D9h

*3

FULL_DATA R/W

DATA

[7:0]

-

0xbe

Full charge cancel point
00-C8h (0-100% step 0.5%)

Dah

CC_CUR_
DATA

R

DATA [7:0]

-

0x00

Battery charging current setting
0x01-0xff (0.02-5.10A step 0.02A)
0x00 Depends on the battery
This register is “read only”, to
change the value, use the register in
PMU registers area.

DBh

To

DCh

BTP2 R/W DATA

[15:0] -

0x000

0

0x0000: Clear the trip point
0x0001-0xffff : (mWh)
When all of the battery’s capacities
lesser than this setting value, the
BTP2 is detected if event is enabled.

Battery
control

DDh

To

DFh

Reserved R/W

Don't

care

- -

*3:

This register is not cleared if the system is in S4-S5 state.

R(/W):

This is the read only register, but the written data will be able to read back till PMU updates the data
periodically, or PMU detects the status change.


3-42

FIC M295 / M296 Service Manual

Advertising
This manual is related to the following products: