Software functional overview – FIC M296 User Manual

Page 90

Advertising
background image

Software Functional Overview

Register

Bit Number

Function Address

Name

R/W

7 6 5

4

3

2

1

0

Logic

De-

fault

Description

B0h

EC_RUN_
ENB

R/W

0:
Disable
1:
Enable

0x00

B1h

EC_WAKE_
ENB

R/W

B
T

P
2

S

M

B

A

L
R
T

RES[4:1]

A
D

P 0:

Disable
1:
Enable

0x00

BTP2:
SMB :
ALRT:
ADP:

BTP2 event
SMBus event.
SMBAlert event.
Adapter event.

B2h

BATT_RUN_
ENB

R/W

0:
Disable
1:
Enable

0x00

B3h

BATT_WAKE
_ENB

R/W

B
T

P

E

M

P

L

O

W

W

A
R

E
R
R

C
A

P

C

/

D

C
O
N

0:
Disable
1:
Enable

0x00

BTP:
EMP:
LOW:
WAR:
ERR:
CAP:
C/D:
CON:

Battery trip point
Empty.
Low battery
Warning
Error
Capacity learning
Charge/Discharge
Battery presence

B4h

GPIO-A_
IO_CONF

R/W CONF_A

[7:0]

0: Input
1:
Output

0x00

B5h

GPIO-A_
DATA

R/W DATA_A

[7:0]

-

B6h

GPIO-A_
RUN_ENB

R/W RUN_ENB_A

[7:0]

0:
Disable
1:
Enable

0x00

B7h

GPIO-A_
EVT_POL

R/W POL_A

[7:0]

0:
Falling
edge
1: Rising
edge

0x00

B8h

GPIO-A_
WAKE_ENB

R/W WAKE_ENB_A

[7:0]

0:
Disable
1:
Enable

0x00

B9h

GPIO-B_
IO_CONF

R/W 1

CONF_B

[6:0]

0: Input
1:
Output

0x80

BAh

GPIO-B_
DATA

R/W 0

DATA_B

[6:0]

-

BBh

GPIO-B_
RUN_ENB

R/W 0 RUN_ENB_B

[6:0]

0:
Disable
1:
Enable

0x00

BCh

GPIO-B_
EVT_POL

R/W 0

POL_B

[6:0]

0:
Falling
edge
1: Rising
edge

0x00

BDh

GPIO-B_
WAKE_ENB

R/W 0 WAKE_ENB_B

[6:0]

0:
Disable
1:
Enable

0x00

BEh

GPIO-C_
DATA

R/W

RES [7 :4]

*4

DATA_C

[3:0]

-

Event/

GPIO

Control

BFh

GPIO-C_
RUN_ENB

R/W 0 0 0

0 0 0

RUN_

ENB_

C

[1:0]

0:
Disable
1:
Enable

0x00

For detail information, refer to GPIO
section in this document.

*4:

Should be 0.


3-40

FIC M295 / M296 Service Manual

Advertising
This manual is related to the following products: