2 pmu08 ec ram list, Software functional overview – FIC M296 User Manual

Page 86

Advertising
background image

Software Functional Overview

Controller
(QR_EC)

#2 EC_DA

TA

R

Query value to
host

Interrupt on
OBF=1


3.8.2 PMU08 EC RAM List

The micro controller PMU08 acts as a supplement for power management control. It supports
the following functions via SMBus Command

( 0x80 , 0xC0 )

Register

Bit Number

Function Address

Name

R/W

7 6 5

4

3

2

1

0

Logic Default Description

00h

*3

Power unit

R(/W)

DATA[15:0] *1

-

0xffff

0x0000: mWh [Fixed value]
0xffff: Unknown

02h

*3

Design
capacity

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

04h

*3

Last Full
Charge
Capacity

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

06h

*3

Battery
Technology

R(/W) DATA[15:0]

*1 -

0xffff

0x0000 : Primary
0x0001: Secondary [Fixed value]
0xffff: Unknown.

08h

*3

Design
Voltage

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mV)
0xffff: Unknown

0Ah

*3

Design
capacity of
Warning

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

0Ch

*3

Design
capacity of
Low

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

0Eh

*3

Battery
capacity
Granularity 1

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

10h

*3

Battery
capacity
Granularity 2

R(/W) DATA[15:0]

*1 -

0xffff

0x0000-0xfffe(mWh)
0xffff: Unknown

12h

*3

Model
number

R(/W)

DATA[15:0] *1

-

0xffff 0x0000 [Not support]

14h

*3

Serial
Number

R(/W)

DATA[15:0] *1

-

0xffff 0x0000 [Not support]

16h

*3

Battery type R(/W)

DATA[15:8]

*1

All bits are 0

CELL_TYP

E

[7:0]

- 0xffff

CELL_TYPE [3:0] This code
depends on battery data format. In the
future, this code may be added.
0x00: NiMH
0x01: Li-ion
0x10: Non-rechargeable battery
(Reserved)

1

st

Battery

[ _BIF ]

18h

*3

OEM
Information

R(/W)

DATA

[15:8]

*1

All bits

are 0

Vender[7:0] -

0xffff

Vender [7:0] This code depends on
battery data format.
And the following name should be
described in the ASL with the same
character code.
In the future, these codes will be
added.
0: “MoliEnergy”
1: “Panasonic”
2: (SANYO does not agree the vender
name display)
3: “TBCL” (Toshiba)
4: “Sony”

*1:

The register type is word.

*3:

This register is not cleared if the system is in S4-S5 state.

R(/W):

This is the read only register, but the written data will be able to read back till PMU updates the data
periodically, or PMU detects the status change.


3-36

FIC M295 / M296 Service Manual

Advertising
This manual is related to the following products: