Frymaster LOV BIELA14 User Manual

Page 12

Advertising
background image

1-5

1.6 Replacing a Heating Element


1. Perform steps 1-5 of section 1.5, Replacing a Temperature Probe.

2. Disconnect the wire harness containing the probe wiring, where the temperature probe is attached

to the element being replaced. Using a pin pusher, disconnect the probe wires from the 12-pin
connector.


3. In the rear of the fryer disconnect the 6-pin connector for the left element (as viewed from the front

of the fryer) or the 9-pin connector for the right element from the contactor box. Press in on the
tabs on each side of the connector while pulling outward on the free end to extend the connector
and release the element leads (see photo below). Pull the leads out of the connector and out of the
wire sleeving.

4. Raise the element to the full up position and support the elements.

5. Remove the hex head screws and nuts that secure the element to the tube assembly and pull the

element out of the frypot. NOTE: The nuts inside the tube can be held and removed using the RE
element tube nut spanner, PN# 2304028. Full-vat elements consist of two dual-vat elements
clamped together. For full-vat units, remove the element clamps before removing the nuts and
screws that secure the element to the tube assembly.


6. If applicable, recover the probe bracket and probe from the element being replaced and install

them on the replacement element. Install the replacement element in the frypot, securing it with the
nuts and screws removed in Step 5 to the tube assembly. Ensure the gasket is between the tube and
element assembly.


7. Route the element leads through the element tube assembly and into the wire sleeving to prevent

chafing. Ensure that the wire sleeving is routed back through the Heyco bushing, keeping it clear
from the lift springs (see photos next page). Also ensure that the wire sleeving extends into the
tube assembly to protect the edge of the tube assembly from chafing the wires. Press the pins into
the connector in accordance with the diagram on the following page, and then close the connector
to lock the leads in place. NOTE: It is critical that the wires be routed through the sleeving to
prevent chafing.

Advertising