Problem probable causes corrective action – Frymaster LOV BIELA14 User Manual

Page 39

Advertising
background image

1-32

Problem

Probable Causes

Corrective Action

M3000 display shows

TEMP PROBE

FAILURE.

A. Problem with the temperature

measuring circuitry including the probe.

B. Damaged computer wiring harness or

connector.

A. This indicates a problem within the

temperature measuring circuitry. Check
resistance of probe, if faulty replace
probe.

B. Swap the computer wiring harness with

one known to be good. If problem is
corrected, replace the harness.

MAINT FILTER

(Manual Filter) won’t

start.

Temperature too low.

Ensure fryer is at setpoint before starting
MAINT FILTER.

M3000 display shows

REMOVE DISCARD.

In non-dedicated mode, a product is
dropped that has a different setpoint that
the current vat temperature.

Remove and discard product. Press a cook
button under the display with the error to
remove the error. Reset the setpoint of the
vat before trying to cook product.

M3000 display shows

HEATING

FAILURE.

Failed computer, failed interface board,
open high-limit thermostat.

Turn off the vat with the issue. The error is
displayed if the fryer loses its ability to heat
oil. It is also displayed when the oil
temperature is above 450°F (232°C) and the
high-limit thermostat has opened, halting the
heating of the oil.

Computer will not go

into program mode or

some buttons do not

actuate.

Failed computer.

Replace computer

M3000 display shows

HI 2 BAD.

Computer in high-limit test mode.

This is displayed during a test of the high-
limit circuit to indicate if the high-limit has
failed.

M3000 display shows

HELP HI-2 or HIGH

LIMIT FAILURE.

Failed high-limit.

This is displayed to indicate the high-limit
has failed.

M3000 display shows

software for only

M3000 or MIB but not

all boards.

Loose or damaged harness

Check that all harnesses between M3000’s,
MIB, AIF and ATO are secure. Ensure
24VDC is present on pins 5 & 6 of J2 on
MIB board and on J4 or J5 of AIF board.
Check for loose or broken pins/wires. If the
problem persists, swap out computer from
one bank to another and cycle power on the
fryer.

M3000 display shows

low temp, heating

indicator cycles on and

off normally but fryer

does not heat.

A.

Three phase power cord unplugged or
circuit breaker is tripped.

B.

Blown fuse

C.

Failed computer.

D.

Damaged computer wiring harness.

E.

Open connection in high-limit circuit.

A.

Ensure all cords are fully seated in the
receptacles, locked into place and that
circuit breakers are not tripped.

B.

Check three amp fuse on front of control
box.

C.

Replace computer.

D.

Replace computer wiring harness.

E.

Check high limit circuit starting at the
control box connector working to the
high-limit.

Advertising