Frymaster LOV BIELA14 User Manual

Page 35

Advertising
background image

1-28

1.13.2 AIF (Auto Intermittent Filtration) Actuator Board Pin Positions and Harnesses

Connector From/To

Harness

PN

Pin

# Function

Voltage

Wire

Color

J1

FV Return

Actuator

N/A

1

Ret + (Open)

24VDC

Black

2

Ret – (Closed)

24VDC

Red

3

Ret Position

Purple

4 Ground

White

J2

FV AIF RTD

1 Ground

White

2

FV - Temp

Red

DV AIF RTD

3 Ground

White

4

DV - Temp

Red

5

6
7
8

Oil Level Sensor

(Gas)

9

DV – OLS (Gas)

10

FV – OLS (Gas)

Locator Pin

11

Locator Vat #5

Black

12

Locator Vat #4

13

Locator Vat #3

14

Locator Vat #2

15

Locator Vat #1

Locator

16

Locator Signal

Black

J3

DV Return

Actuator

N/A

1

Ret + (Open)

24VDC

Black

2

Ret – (Closed)

24VDC

Red

3

Ret Position

Purple

4 Ground

White

J4

MIB J2 or

AIF J5

8074547

AIF Board

Communication

and Power

1 Ground

Black

2

CAN Lo

Red

3

CAN Hi

White

4 5VDC+

5VDC Black

5 24VDC

24VDC Red

6 Ground

White

J5

AIF J4 or

ATO J10

8074547

AIF Board

Communication

and Power

1 Ground

Black

2

CAN Lo

Red

3

CAN Hi

White

4 5VDC+

5VDC Black

5 24VDC

24VDC Red

6 Ground

White

J6

FV Drain
Actuator

N/A

1

Drain + (Open)

24VDC

Black

2

Drain – (Closed)

24VDC

Red

3

Drain Position

Purple

4 Ground

White

J7

DV Drain

Actuator

N/A

1

Drain + (Open)

24VDC

Black

2

Drain – (Closed)

24VDC

Red

3

Drain Position

Purple

4 Ground

White

Advertising