Frymaster LOV BIELA14 User Manual
Page 35

1-28
1.13.2 AIF (Auto Intermittent Filtration) Actuator Board Pin Positions and Harnesses
Connector From/To
Harness
PN
Pin
# Function
Voltage
Wire
Color
J1
FV Return
Actuator
N/A
1
Ret + (Open)
24VDC
Black
2
Ret – (Closed)
24VDC
Red
3
Ret Position
Purple
4 Ground
White
J2
FV AIF RTD
1 Ground
White
2
FV - Temp
Red
DV AIF RTD
3 Ground
White
4
DV - Temp
Red
5
6
7
8
Oil Level Sensor
(Gas)
9
DV – OLS (Gas)
10
FV – OLS (Gas)
Locator Pin
11
Locator Vat #5
Black
12
Locator Vat #4
13
Locator Vat #3
14
Locator Vat #2
15
Locator Vat #1
Locator
16
Locator Signal
Black
J3
DV Return
Actuator
N/A
1
Ret + (Open)
24VDC
Black
2
Ret – (Closed)
24VDC
Red
3
Ret Position
Purple
4 Ground
White
J4
MIB J2 or
AIF J5
8074547
AIF Board
Communication
and Power
1 Ground
Black
2
CAN Lo
Red
3
CAN Hi
White
4 5VDC+
5VDC Black
5 24VDC
24VDC Red
6 Ground
White
J5
AIF J4 or
ATO J10
8074547
AIF Board
Communication
and Power
1 Ground
Black
2
CAN Lo
Red
3
CAN Hi
White
4 5VDC+
5VDC Black
5 24VDC
24VDC Red
6 Ground
White
J6
FV Drain
Actuator
N/A
1
Drain + (Open)
24VDC
Black
2
Drain – (Closed)
24VDC
Red
3
Drain Position
Purple
4 Ground
White
J7
DV Drain
Actuator
N/A
1
Drain + (Open)
24VDC
Black
2
Drain – (Closed)
24VDC
Red
3
Drain Position
Purple
4 Ground
White