Frymaster LOV BIELA14 User Manual

Page 44

Advertising
background image

1-37

1.14.6 M3000 Filter Error Flowchart

Change filter pad and

ensure filter pan is

pulled out for a

minimum of 30

seconds.

Fryer returns to

cook mode for 4

minutes or 15

minutes if pad

change expired.

NORMAL

OPERATION

RESUMES

SIXTH

CONSECUTIVE

FILTER ERROR

Fryer returns to

cook mode for 15

minutes.

TECH

ENTERS

CODE

MESSAGE

DISPLAYED

Call an Authorized

Repair Technician


If the computer displays SERVICE
REQUIRED, the fryer can be used in
most cases by answering NO when the
prompt for SYSTEM ERROR
FIXED? YES NO is displayed. The
message repeats every 15 minutes until
the issue is repaired and error cleared by
a technician. To clear the error, enter
1111 after answering YES when
SYSTEM ERROR FIXED? YES
NO is displayed.

This chart follows the process of clearing a filtration
issue. The prompt is displayed when any of the
following occur:

1. a clogged filter pad,
2. a tripped or defective filter pump,
3. a leaky O-ring on the pick-up tube,
4. a failed drain valve/actuator, or
5. a failed return valve/actuator.

Advertising