Frymaster 45 Series User Manual

Page 11

Advertising
background image

1-5

Gas

Pressure

Natural

3.5" W.C.

0.73 kPa

Propane

8.25" W.C.

2.05 kPa

Non-CE Standard

Burner Manifold Gas Pressures

Gas

Pressure

(mbar)

Natural Gas Lacq
(G20) under 20 mbar

7,5

Natural Gas Gronique *
(G25) under 25 mbar

10

Natural Gas Gronique
(G20) under 20 mbar

10

Propane
(G31) under 37 or 50 mbar

20,6

CE Standard

Burner Manifold Gas Pressures

* Belgian G25 = 7,0 mbar

4. If the measured gas pressure does not match the appropriate pressure in the tables above, remove

the cap from the gas valve regulator and adjust to the correct pressure.

Robertshaw Valve

(Non-CE Units)

Honeywell Valve

(Non-CE Units)

Honeywell Valve

(CE Units)

Regulator Adjustment Screw Cap

5. Place the fryer power switch and the gas valve in the OFF position. Remove the fitting from the

pressure tap hole and reinstall the plug. Place the gas valve in the ON position, and check for and
eliminate any gas leaks. Place the gas valve in the OFF position.


1.4

Adjusting the Pilot Flame

1. On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the

pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to de-
crease the length of the flame. Adjust the flame to a length of 1 to 1½ inches (25 to 38mm).

Robertshaw Valve

(Non-CE Units)

Honeywell Valve

(Non-CE Units)

Honeywell Valve

(CE Units)

To access the pilot adjustment screw on

Non-CE valves, this cap must be removed.

Pilot Adjustment Screw


2. On Non-CE valves, reinstall the pilot adjustment screw cap.