1.10.4 Troubleshooting the Thermostat

Turn the fryer on and

set the thermostat

control knob to the

maximum setting.

Does the

burner light?

Is the

thermostat properly

calibrated?

Thermostat is OK.

Yes

Yes

Is 24VAC

present at the gas

valve?

Probable cause is

a failed thermostat.

No

Probable cause is
a failed gas valve.

Yes

No

While it is still hot, inspect the thermostat

body for damage. Inspect leads for fraying,

burning, breaks, and/or kinks. Replace

thermostat if it is bent, dented, or cracked,

or if leads are damaged.

Allow the cooking

oil/shortening to

cool to at least 15

degrees below the

thermostat setting.

Remove the leads

from the terminal

block and check

continuity.

Is continuity

OK (resistance is

zero)?

Thermostat has

failed.

Replace the leads

in the terminal

block.

Is resistance

of wire from terminal

block to gas valve

zero?

No

Yes

No

Probable cause

is a break or short

in the wiring.

No

Thermostat and

associated wiring

are OK.

Yes