Frymaster 45 Series User Manual

Page 34

Advertising
background image

1-28

1.9.8 Interpretation of Digital Controller Lights

Power light on, heat light cycling, trouble light off, and melt light on:

• If fryer oil temperature is below 180ºF (82ºC), the lights indicate the unit is operating nor-

mally.

• If the oil temperature is above 180ºF (82ºC) and the heat light continues to cycle as if in the

melt cycle, this may indicate a defective probe circuit or low incoming 12VAC to the con-
troller.

Power light on, heat light on, trouble light off, and melt light off:

• If the fryer oil temperature is above 180ºF (82ºC) and below the setpoint temperature, the

lights indicate the unit is operating properly.


• If the oil temperature is above the temperature set on the control knob and the heat light re-

mains lit, this may indicate a defective probe circuit.


Power light on, heat light off, trouble light on, and melt light off:

• If the fryer oil temperature is below 410ºF (210ºC), the lights indicate one of the following:

a. The probe circuit is defective, or

b. There is a connection problem on pins 2 or 10 on the 15-pin wiring harness.

• If the fryer oil temperature is above 410ºF (210ºC), the lights indicate a run-away heating cir-

cuit.

1.10 Troubleshooting

Guides

The troubleshooting guides found in the pages that follow are intended to assist service technicians
in quickly isolating the probable causes of equipment malfunctions by following a logical, step-by-
step process.

Advertising