Frymaster 45 Series User Manual

Page 38

Advertising
background image

1-32

1.10.3 Troubleshooting the Gas Valve

Verify that gasmain

street valve is open and

fryer gasline cutoff valve

is open.

Verify gas valve is

in ON position.

Is 24VAC

present at the gas

valve?

Problem is in the 24VAC

circuit. See Troubleshooting

the 24VAC Circuit on Pages

1-29 and 1-30.

No

For which gas is

the fryer

configured?

Natural

Propane

Is incoming

gas pressure 6-14"

WC (1.49-3.49

kPa)?

Is incoming

gas pressure 11-14"

WC (2.74-3.49

kPa)?

Problem is with

fryer gas supply.

No

No

Place the ON/OFF

or POWER switch

in the ON position

and light the pilot.

Yes

Yes

Does the pilot

remain lit?

Is output from

the thermopile approximately

400 millivolts?

Is continuity

of the high-limit switch

zero?

Problem is a

failed gas valve.

Probable cause is a

failed thermopile.

Probable cause

is a failed high-limit

switch.

No

Yes

No

No

Yes

Yes