1.10.1 Troubleshooting the 24VAC Circuit in Units without Interface Boards

Yes

Is 24VAC

present at the gas

valve?

Is 24VAC

present at the ON/OFF

switch?

No

Verify that the

ON/OFF switch

is in the ON

positon.

Is the continuity

of the ON/OFF switch OK

(zero resistance in the ON

position)?

Yes

Verify that the temperature

of the cooking oil/

shortening is at least 15

degrees below the

thermostat setting.

Is continuity of

the thermostat OK (zero

resistance)?

Probable cause

is a failed 24-volt

transformer.

No

Probable cause

is a failed ON/OFF

switch.

No

Probable cause is a

failed thermostat.

No

Problem is with the gas valve.

Refer to Troubleshooting the Gas

Valve on Page 1-33.

Yes

Yes