Frymaster 45 Series User Manual

Page 17

Advertising
background image

1-11

3. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its

tabs from the hinge slots in the mounting frame.


4. Carefully press the light out from the back of the control panel. Disconnect one wire at a time

and reconnect it to the replacement light until all wires are transferred.


5. Carefully press the light back into the control panel.

6. Reverse steps 1-3 to reassemble the fryer.

1.8.7 Replacing the Power or Melt Cycle Switch in Fryers with Thermostat Controls

1. Disconnect the fryer from the electrical supply.

2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws

from the upper left and right corners of the control panel. The control panel is hinged at the bot-
tom and will swing open from the top.


3. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its

tabs from the hinge slots in the mounting frame.


4. Using a flat-tipped screwdriver, disconnect the chrome bezel from the tabs on the switch and

press the switch out from the front.

5. Carefully press the new switch back into the chrome bezel, making sure the tabs on the switch

engage the slots in the bezel.


6. Disconnect one wire at a time from the old switch and reconnect it to the new switch until all

wires have been transferred.

7. Reverse steps 1-3 to reassemble the fryer.

1.8.8 Replacing the Melt Cycle Timer in Fryers with Thermostat Controls

NOTE: In early 1999, PC board melt cycle timers replaced melt cycle timer motors in new fryers.

1. Disconnect the fryer from the electrical supply.

2. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws

from the upper left and right corners of the control panel. The control panel is hinged at the bot-
tom and will swing open from the top.


3. Remove the screws securing the timer motor (or the PC board timer bracket) to the fryer (see il-

lustration on Page 2-16).


4. Remove one wire at a time and reconnect it to the replacement PC board timer until all wires

have been transferred.


5. Reverse steps 1-3 to reassemble the fryer.

Advertising