Furuno FR-2115-B User Manual

Page 23

Advertising
background image

2-4

2.1.2 Fabricating signal cable S03-75

1. Remove the vinyl sheath by 450 mm.

2. Slide the clamping ring, washer, rubber gasket

and washer onto the signal cable in that order.

3. Unravel the outer shield to expose the cores in

the outer layer. Then, unravel the inner shield to

expose the cores in the inner layer. Label all

inner cores to aid in identification.

4. Attach EMI cores to all inner cores and all outer

cores, and bind them with cable ties, etc. Note

that there are two types of the EMI cores, thick

and thin.

5. Trim each core (except coaxial wire) considering

its location on the terminal board in the antenna

unit.

6. Trim the inner and outer shields leaving 500 mm

each. Twist shields together and attach crimp-on

lug FV5.5-4 (blue,

φ

4).

7. Remove insulation of each core by about 6 mm.

Fix crimp-on lug FV1.25-3 (red,

φ

3) to each core.

8. Fabricate the coaxial cable. Make the length 10

mm longer than the shield to prevent wire strain.

Attach crimp-on lug FVD1.25-3 (red,

φ

3) to

coaxial cable.

Clamping
ring

Washers

Rubber
gasket

Crimp-on lug
FV5.5-5
(Blue,

φ

4)

Figure 2-7 How to ground

signal cable S03-75

Figure 2-6 How to fabricate

signal cable S03-75

VINYL SHEATH

Inner shield

6 mm

Crimp-on lug
FV1.25-M3
(Red,

φ

3)

450 mm

45 mm

Crimp-on lug
FVD1.25-3
(Red,

φ

3)

2C-2V

Cut here

50 mm

6 mm

Fold four times

Crimp-on lug
FV1.25-3
(Red,

φ

3)

75 mm

500mm

Coax cable

Outer cores

Inner cores

= EMI cores
Outer cores: RFC-13 (thick)
Inner cores: RFC-10 (thin)

Cable tie

Under

100 mm

70-130 mm

Advertising