8 4.2.2 arp board adjustment – Furuno FR-2115-B User Manual

Page 47

Advertising
background image

4-8

4.2.2 ARP board adjustment

1. Turn the GAIN, A/C SEA and A/C RAIN controls fully counterclockwise (OFF). Transmit on

the 12 nm range.

2. Connect a digital multimeter between TP7(+) and TP6(-) on the ARP Board.

TP7

TP6

R104

R103

Figure 4-6 ARP Board (18P9002B)

3. Adjust R104 on the ARP Board so the multimeter reads between 0.09 and 0.14 VDC.

4. Set controls and switches as below.

5. GAIN: fully clockwise (max.)

Interference rejector: OFF

Range: 24 nm

Echo stretch: OFF

6. Press [RADAR MENU] [0] [0] [0] [2] [0] to open the INITIAL SETTING2 menu.

7. Set the VIDEO SIG field to DIGITAL and press the [ENTER] key.

8. Adjust R103 on the ARP Board so noise just appears on the display.

Too little noise

Proper noise

Too much noise

Figure 4-7 How to adjust noise

9. Set VIDEO SIG to ANALOG and press the [ENTER] key.

Advertising