3 4.1.2 connection of external power supply, 3 dip switch, jumper wire settings – Furuno FR-2115-B User Manual

Page 42

Advertising
background image

4-3

4.1.2 Connection of external power supply

An external power supply is necessary when the repeater signal is step-by-step type and the

step voltage is below 20 V or output voltage is less than 5 W.

1. Cut the jumper wire JP1 on the GYRO CONVERTER Board when an external power supply

is used.

2. Connect the gyro cable and power cable as shown below.

GYRO CONVERTER Board

[A] 64P1106

1 R2

Either connection
in case of DC
polarity.

J5

2 R1/COM

External Power Supply
20 - 135 VAC
20 - 100 VDC

1S1

2 S2

3 S3

4 T

5 F.G.

Gyrocompass
(Step type)

S1

S2

S3

COM

F.G.

J4

Figure 4-3 Connection of external power supply to GYRO CONVERTER Board

4.1.3 DIP switch, jumper wire settings

Default setting

The default setting of all DIP switches is off and all jumpers wire are set to "#1". (Note that the

jumper wire JP1 is set at #1, #2, and #3.) In those settings the gyrocompass having the

following characteristics can be directly connected; modification of the GYRO CONVERTER

Board is not necessary.

AC synchronous signal: 50/60 Hz

Rotor voltage: 60 to 135 V AC

Stator voltage: 60 to 135 V AC

Gear ratio: 360X

Supply voltage: 30 to 135 V AC

If the specifications of the gyrocompass differ from those mentioned above, change jumper wire

and DIP switch settings on the GYRO CONVERTER Board as appropriate. Settings may be

changed according to gyrocompass specifications (page 4-4) or make and model of

gyrocompass (page 4-5). For the location of DIP switches and jumper wires, see page 4-6.

Advertising