Caution – Furuno FR-2115-B User Manual

Page 28

Advertising
background image

2-9

2.3.2 Connection of monitor cable inside the monitor

Connect the monitor cable inside the monitor as below.

MONITOR
REAR
VIEW

Loosen two M4X10
pan-head screws.

Cable Entrance Plate

NH5P to J575
NH6P to J577

NH3P to J579
VH3P to J576

Connect D-SUB
connector to J560
on the INTERFACE
Board.

Fasten ground wire with
M4X10 pan-head screw.

Unfasten top or bottom M4X10
pan-head screw fixing clamp plate.
Lay cable in clamp and then close
clamp plate.

Clamp Plate

MONITOR CABLE

CONNECTOR Board

Fasten D-SUB connector
with screw.

1. Fasten cable

entrance
plate.

2. Close cable
cover.
3. Fasten ground

wire between
earth terminal
and ship's
superstructure.

Earth Terminal

1

2

3

4

5

Connect to
CONNECTOR Board.

INTERFACE Board

Ground the equipment
to prevent electrical
shock and mutual
interference.

CAUTION

Cable Cover

Unfasten three MX10
screws to remove cable
entrance plate.

Figure 2-12 Connection of monitor

Advertising