2 static trial maneuver, Figure 5-14 arpa 2 menu – Furuno FR-2125V User Manual

Page 104

Advertising
background image

5-22

A8

A7

A6

A5

A4

A3

A2

A1

A0

B8

B7

B6

B5

B4

B3

B2

B1

B0

OS0

OS1

OS2

OS3

OS4

OS5

OS6

OS7

OS8

Present own ship
position

Delay time = 5 min.

A

B

T

Figure 5-13 Trial maneuver

Note that once a dynamic trial maneuver is initiated, you cannot alter own ship’s trial
speed, course or delay time until the trial maneuver is terminated.

5.16.2 Static trial maneuver

A static trial maneuver displays only the final situation of the simulation. If you enter the
same trial speed, course and delay time under the same situation as in the aforemen-
tioned example of dynamic trial maneuver, the screen will instantly show position OS7 for
own ship, position A7 for target A and position B7 for target B, omitting the intermediate
positions. Thus, the static trial maneuver will be convenient when you wish to know the
maneuver result immediately.

Note: For accurate simulation of ship movements in a trial maneuver, own ship’s charac-
teristics such as acceleration and turning performance should be properly set in the initial
settings at the time of installation.

To perform a trial maneuver:

1. Press the [PLOT MENU] key followed by the [0] key to show the ARPA 2 menu.

[ARPA (2)]
1 [ARPA (1)]
2 TRIAL MODE

STATIC/DYNAMIC

3 HISTORY

OFF/ON

4 HISTORY POINTS

5/10/20

5 HISTORY INTERVAL

30SEC/1/2/3/6MIN

6 MARK SIZE

STD/LARGE

7 GUARD, ACQ STABILIZE

NORTH/CRT

8 [INPUT SIG CHECK (1)]
9 [ARPA TRACK TEST]
0

Figure 5-14 ARPA 2 menu