3 terminating trial maneuver – Furuno FR-2125V User Manual

Page 105

Advertising
background image

5-23

2. Press the [2] key to select TRIAL MODE.

3. Further press the [2] key to select (or highlight) STATIC or DYNAMIC as appropriate.

4. Press the [ENTER] key to conclude your selection followed by the [1] key to go back to

the ARPA 1 menu.

5. Press the [9] key on the ARPA 1 menu. The TRIAL DATA SETTING menu appears at

the screen bottom associated with the current own ship’s speed and course readouts.

TRIAL DATA SETTING
[DYNAMIC MODE]*

SPEED (VRM)

= 15.0KT

COURSE (EBL)

= 53.6

°

DELAY TIME (KEY) = xx.xMIN
TRIAL TIME

= xx.xMIN

* STATIC MODE when static mode
is selected.

Figure 5-15 TRIAL DATA SETTING menu

6. Enter own ship’s intended speed, course and delay time in the following manner:

Speed:

Set with the VRM control.

Course:

Set with the EBL control.

Delay time: Enter in minutes by hitting numeric keys. This is the time after which own

ship takes a new situation, not the time the simulation begins. Change the
delay time according to own ship loading condition, etc.

Trial time:

Enter in minutes by hitting numeric keys. This is the length of the trial time
in minutes.

7. Press the [ENTER] key to start the trial maneuver.

Trial maneuver takes place in three minutes with the letter “T” displayed at the bottom of
the screen. If any tracked target is predicted to be on a collision course with own ship (that
is, the target ship comes within preset CPA/TCPA limits), the target plot symbol changes
to a triangle and flashes. If this happens, change own ship’s trial speed, course or delay
time to obtain a safe maneuver. The trial maneuver is automatically terminated and the
normal radar picture is restored three minutes later.

5.16.3 Terminating trial maneuver

Press the [PLOT MENU] key.

Advertising